Atomic Absorption Spectrophotometer LAAS-A11 Catalog

Download Catalog

Atomic Absorption Spectrophotometer LAAS-A11

Overview

Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting. Its double beam system automatically compensates the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift so as to reach a good basic line stability. The specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration in this atomic absorption spectrophotometer. It has multiple applications in research and development and industrial analysis.

Features :

  • Double Beam system to compensate the light source drift and wavelength drift
    Build-in computer data processing and LCD display
    No pre-heating of Cathode lamp for a long time to analyze the sample
    High precision of measurement
    Multi-functional analysis mode
    Fast analysis of sample
    High energy optical path
    Safe and reliable gas path system
    Electronic circuit drift to reach a good basic line stability
  • Specifications :
    Monochromator
    Wavelength range 190 - 900 nm
    Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
    Wavelength accuracy ≤ ± 0.5 nm
    Wavelength repeatability ≤ 0.3 nm(single direction)
    Baseline drift ± 0.004 Abs / 30 min
    Grating groove density
    Sample Volume
    The volume of sample
    Repeated Sampling Frequency
    Cleaning and waste container volume
    Absorbance Range
    The Program
    Temperature Range
    Detector
    Heating Mode
    Temperature Control Method
    Temperature Control
    Resolution < 40 %
    Lamp holder
    Lamp current adjustment range
    Lamp power supply mode
    Optical System
    Atomization Chamber
    Characteristics Volume
    Characteristic concentration (Cu) ≤ 0.04 mg / ml / 1 %
    Detection Limit
    Detection Limit (Cu) 0.008 mg/ml
    Background calibration ability Greater than 30 times
    Burner
    Nebulizer
    Precision
    Ignition Type
    Sprayer
    Room Spray
    Sample Tray
    The Smallest Lincrement
    Safety measures
    Gas Control
    Measurement
    Concentration calculation
    The Cooling Water
    The number of repeated measurements
    Print results
    Software Environment
    Operating temperature
    Working humidity
    Power supply 220 V / 3 A, 50 Hz
    Power (VAC)
    Gross Weight 160 kg
    Weight
    Dimension (L × W × H) 1220 x 770 x 730 mm
    Optional Accessories :

    A graphite furnace system
    Titanium burner—5cm
    Nitrous oxide generator
    Hydride generator
    Graphite tubes
    Acetylene regulator
    Nitrous oxide regulator Software
    Recirculating cooling water system

    Applications :

    Atomic absorption spectrophotometer is used to analyze elements in agriculture, chemical, environmental study, food, mining, and petrochemical, pharmaceutical industries.