Atomic Absorption Spectrophotometer LAAS-A20

Overview

Atomic absorption spectrophotometer designed with the latest technology, can automatically accomplish safety ignition and reproducibility of the flame method. The graphic analysis system gives information on analysis of the whole process e.g. measured value, temperature, procedures, time, etc. It consist of hollow cathode lamp to improve the analysis efficiency and accuracy of the flame & deuterium lamp for background correction.

Features :

  • 1800 /mm reticle (dispersion rate) large area grating Monochromator
    Titanium burner for the flame analysis
    Polymer automization chamber
    Automatic analysis ensures sensitivity and reproducibility of the flame method
    Light source 6 lamp holder
    Graphic furnace system gives information on analysis of the whole process
    Convenient data processing & sharing & printing
    Powerful software with automatic instrument and additional control
  • Specifications :
    Monochromator
    Wavelength range 180 - 900 nm
    Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
    Wavelength accuracy ≤ 0.15 nm
    Wavelength repeatability ± 0.1 nm
    Baseline drift ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic)
    Grating groove density
    Sample Volume
    The volume of sample
    Repeated Sampling Frequency
    Cleaning and waste container volume
    Absorbance Range 0 - 4 A
    The Program
    Temperature Range
    Detector Imported photomultiplier tube
    Heating Mode
    Temperature Control Method
    Temperature Control
    Resolution
    Lamp holder ≤ 6 lamps automatic turret, automatic alignment
    Lamp current adjustment range
    Lamp power supply mode pulsed power supply
    Optical System large 1800 /mm grating ruling, full closed optical system
    Atomization Chamber Polymer explosion-proof spray chamber
    Characteristics Volume
    Characteristic concentration (Cu) 0.015 μg / mL / 1 %
    Detection Limit
    Detection Limit (Cu) 0.002 μg/mL
    Background calibration ability
    Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
    Nebulizer Atomizer efficient glass atomizer,can also be customized
    Precision RSD ≤ 0.5 %
    Ignition Type Microcomputer control, automatic ignition
    Sprayer
    Room Spray
    Sample Tray
    The Smallest Lincrement
    Safety measures
    Gas Control Automatic gas control system
    Measurement Flame method, Hydride generation-Atomic absorption method
    Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
    The Cooling Water
    The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
    Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
    Software Environment
    Operating temperature
    Working humidity
    Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
    Power (VAC)
    Gross Weight
    Weight
    Dimension (L × W × H)
    Applications :

    Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.